The ASD 531 is small, yet extremely powerful.
As with the two larger models in the ASD range, it is also equipped with the tried-and-tested HD detector with LVSC (large-volume smoke chamber). Its outstanding sensitivity ensures high levels of safety, combined with an impressively long service life. The ASD 531 ignores individual disruptive factors effectively thanks to its patented lint filter.
The ASD 531 is the perfect choice for anyone wanting to put a smaller system into operation quickly and easily without the need for extra training. Configuration is made directly on the device using BasiConfig in just three simple steps without the need for a PC.
Operation of the compact device is just as easy. With the ASD 531, you can monitor your rooms and premises reliably and precisely with a minimum of effort and exceptional cost efficiency.

Key Features
- ASD 535 1 - Aspirating smoke detector including 1 integrated smoke sensor, without smoke level indicator
ASD 531 - for small premises:
- Compact Design
- Permissable Temperature Range: - 10.C to +55 .C
- Maximum Sampling Pipe Length: 75m
- Approval: VdS, UL*, FM*
Applications
The ASD 531 is ideal for property and space surveillance thanks to its excellent response behaviour. Typical applications include:
Room surveillance
- Electronic Measuring Rooms
- Transformer Rooms
- Clean Rooms
- Elevator Shafts
- False Ceilings
- Ventilation Ducts
Property surveillance
- Telecommunication facilities
- High and low-voltage distribution cabinets
- Display cases
- IT installations
- CNC control systems
Modules & Accessories
Optional Modules:
- RIM 36 - Optional Modules with 5 Additional Relays
- SD Card - Industrial SD Card
- UMS 35 - Universal module support for mounting line modules
- ASD PipeFlow - PC Tool for Drawing and Calculating the Sampling Pipe
Accessories:
An extensive range of accessories are available (25 mm and ¾" sampling tube, sampling points, filters, water separators, etc.).
View the range of Securiton Pipes & Fittings that Patol offer alongside the ASD 531.
Technical Data
Supply Voltage Range | EN 54 FM/UL |
14.5-30 VDC 16.4-27 VDC |
Power Consumption | Typical For 24 VDC | 75 mA |
Sampling Tubes/Smoke Sensors | Quantity | 1 |
Alarm Sensitivity | Alarm Pre-Signal |
0.02-10%/m From 0.006%/m |
Alarm Levels | 4 (3 Pre-Signals Fixed in Adv. 30/50/70%) |
|
Autolearning, Day/Night Switching | Not Available | |
Relays |
1-Channel Vers. 2-Channel Vers. |
2 (1 Alarm, 1 Fault) (Use RIM 36 for Pre-Signals) |
Interfaces |
O.C. Outputs PC Tools Network Inputs |
See Relays - - Reset |
Optional Modules |
Quantity Types |
2 RIM 36 |
Standards/Approvals |
EN 54-20 EN 54-27 (Ventil, Ducts) UL 268, FM 3230 Other Compliance |
VdS G 208 154 Yes Planned - EMC, CPR, RoHS |
Number of Campling Apetures (with ASD PipeFlow) |
EN 54-20 Class A EN 54-20 Class B EN 54-20 Class C NFPA 72 (UL/FM) |
6 8 12 12 |
Monitoring Area | Max.Area | 720m2 |
System Limits as per EN 54-20 Class C |
Max. Quantity Sampling Apertures Max. Length to Last Sampling Point Max. Overall Length for all Sampling Tubes |
12 40m 75m |
System Limits without Conformity to Standards | Max. Overall Length for All Sampling Tubes | - |
Configuration |
Close Operation PC Tool |
BasicConfig - |
Fan/Sampling System |
Suction Pressure Service Life (MTTF) Performance Levels Suction Noise Soundproof Housing |
> 100 Pa > 80, 000 h (at 40.C) 1 <32 db="" a="" 1m="" distance="" p=""> < 20 dB (A)
|
Housing |
EN 60529 Prot. Category Dimensions ( W x H x D) Weight (Approx.) Cable Entries |
IP 54 195 X 290 X 140 mm 1950g 3 x M20, 1 X M25 |
Operating Temperature/Humidity | Evaluation Unit | -20 - +55.C/95% RH (Amb. Air Max. +40.C) |
Display and Operation - Standard | Per Channel | 1 < |
Display and Operation - Enhanced | 10 LEDs (Yellow) for Smoke Level Indicator | Not Available |
Event Menory/ Analogue Values |
On Board With SD Card |
1000 Events On-Board Slot for SD Card |